ups_eaton_9px: walk: #- upsIdentName # Serial number => xupsIdentSerialNumber - xupsBatCapacity # % of charged - xupsBatTimeRemaining # run time in seconds before UPS turns off - xupsBatVoltage # battery voltage - xupsBatteryAbmStatus # Advanced Baterry Management status - xupsBatteryAged # Indicates if the battery is over aged. - xupsBatteryFailure # Indicates if a battery fault detected or battery tests failed. - xupsBatteryLastReplacedDate # latest baterry replacement date #- xupsBatteryLowCapacity # Indicates if the battery capacity is below the threshold set in the UPS. - xupsBatteryNotPresent # Indicates if the UPS has no battery either internal or external. - xupsBypassVoltage # Bypass voltage #- xupsBypassAverageVoltage # AVG Bypass voltage #- xupsBypassCurrentHighPrecision # The measured bypass current from the UPS meters in tenth of amps. - xupsBypassFrequency # Bypass frequency in tenths of Hz # xupsBypassNumPhases # The number of lines in the UPS bypass table. - xupsBypassTotalCurrent # Bypass current from UPS in tenth of amps - xupsEnvAmbientTemp # Ambient temperature in the vicinity - xupsIdentManufacturer # Manufacturer name => EATON - xupsIdentModel # Model name #- xupsIdentOemCode # A binary code indicating who the UPS was manufactured or labeled for - xupsIdentPartNumber # P/N - xupsIdentSerialNumber # S/N - xupsIdentSoftwareVersion # SW version - xupsInputAverageVoltage # The measured input voltage from the UPS meters in volts - xupsInputFrequency # The utility line frequency in tenths of Hz. #- xupsInputId # value indicates what measurement is being stored in this table row : phase1 to neutral, phase2 to neutral, phase3 to neutral, phase1 to phase2, phase2 to phase3, phase3 to phase1. - xupsInputNumPhases # The number of input phases (normally 1 to 3). #- xupsInputSource_info # The present status of the primary AC input of the UPS # ERROR? - xupsInputVoltage # The measured input voltage from the UPS meters in volts. - xupsOutputCumulativePowerUsage # Energy consumed since last reset - xupsOutputCurrent # The measured UPS output current in amps. - xupsOutputCurrentHighPrecision # The measured UPS output frequency in tenths of Hz. - xupsOutputFrequency # The measured UPS output frequency in tenths of Hz. #-xupsOutputId # value indicates what measurement is being stored in this table row : phase1 to neutral, phase2 to neutral, phase3 to neutral, phase1 to phase2, phase2 to phase3, phase3 to phase1. - xupsOutputLoad # The UPS output load in percent of rated capacity. - xupsOutputNumPhases # The number of metered output phases. - xupsOutputPercentLoad # The percentage of the UPS power capacity presently being used on this output line. #- xupsOutputSource_info # The present source of output power. #- xupsOutputStatus_info # The present status of the AC output of the UPS. # ERROR? - xupsOutputTotalCurrent # The measured output current from the UPS meters in tenth of amps. #- xupsOutputTotalVA # The measured output apparent power in VA. - xupsOutputTotalWatts # The measured output active power in watts. - xupsOutputWatts # The measured real output power in watts. - xupsOutputVoltage # The measured output voltage from the UPS metering in volts. lookups: - source_indexes: [ xupsOutputPhase ] lookup: xupsOutputName - source_indexes: [ xupsInputPhase ] lookup: xupsInputName - source_indexes: [ xupsBypassPhase ] lookup: xupsBypassName overrides: xupsBatteryAbmStatus: type: EnumAsInfo xupsOutputStatus: type: EnumAsInfo xupsOutputSource: type: EnumAsInfo xupsInputStatus: type: EnumAsInfo xupsInputSource: type: EnumAsInfo xupsIdentSerialNumber: type: DisplayString xupsOutputName: type: DisplayString xupsInputName: type: DisplayString xupsBypassName: type: DisplayString ignore: true xupsIdentPartNumber: type: DisplayString xupsBypassPhase: ignore: true xupsBypassId: ignore: tru